@Dammit steering boss is the simplest solution, appx £183 from porscheshop
-
-
-
-
-
-
-
-
-
-
-
-
-
Nothing wrong with that approach as with two metered connections (1 public, 1 private I assume) and two isolators (and protective devices I assume) a fault condition in one CU shouldn't take out the other supply.
Also adds a degree of future flexibility as iirc you're rebuilding the property and may at some point wish to move the house CU.
-
you'll need an electrician, and likely materials and services:
x metres 3 core PVC/SWA/PVC and appropriate glands
burying tape
4 way consumer unit
likely earth terminal and possibly earth rod dependent on IT/TT
outgoing mcb from existing consumer unit in the house (you do have a spare way..?)
incoming 30mA rcd breaker for garage CU
outgoing mcb for sockets
outgoing mcb for lights
x metres 2.5mm T&E for power
x metres 1.5mm T&E/3&E for lights
accessories for above
consumables
building works and making good
inspection, test and certification
say 2 full days work, maybe 3appx >£1,000 for a NICEIC tech, less for a bodger
-
-